BQZ – Outdoor Air Cooled Quiet Scroll Condensing Units
June 29, 2016BEZ – Indoor/Outdoor Air Cooled Scroll Condensing Units
June 29, 2016BES – Indoor/Outdoor Air Cooled Semi-Hermetic Condensing Units
CONTACT A PRODUCT SPECIALIST TODAY:
See our Product Data and Specifications for full details (PDF)
We offer a complete line up of “Generation D” condensing units that meet or exceed the new “AWEF” requirements for condensing units. Use this guide which collects all of the AWEF numbers for compliant equipment: https://docs.b-rp.ca/awef/br_awef_quick_reference.pdf
Have questions about AWEF, WICF, etc.? Visit our AWEF-FAQ
Certification:
Most models meet or exceed the new “AWEF” requirements for condensing units. Use this guide which collects all of the AWEF numbers for compliant equipment: https://docs.b-rp.ca/awef/br_awef_quick_reference.pdf
Features:
Indoor Unit:
- Compatible with Low GWP Refrigerants
- Weatherproof electrical control box with compressor contactor and fused control circuit
- Spring mounted accessible semi-hermetic compressor with suction and discharge vibration eliminator
- High efficiency enhanced tube and fin condenser design
- Energy efficient PSC condenser fan motor
- Receiver with fusible plug and liquid shut off valve
- Fixed high pressure switch and adjustable low pressure control
- Receiver inlet and outlet shutoff valve (8HP and above)
- Suction service valve
- Pre-formed copper tubing
- Unit leak tested and shipped with Helium holding charge
- Electronic liquid injection on L8 units
- Painted cabinet
Outdoor Unit: All Standard Features of Indoor Unit, Plus:
- Painted outdoor weather-resistant housing with removable hood
- Flooded head pressure control (non adjustable) 150 PSIG for optimal efficiency
- Adjustable head pressure control on large 2 fan models
- Crankcase heater
- Fan cycling control (all 2 fan models)
Available Options:
- Suction accumulator
- Suction accumulator with boil-out coil
- Discharge line Check valve
- Oil separator
- Oil separator c/w oil return filter & solenoid valve
- Adjustable head pressure control valves
- Receiver inlet ball valve (standard on 2 fan models)
- Heated and Insulated receiver
- Over-sized receiver
- Sealed liquid line filter drier & sight-glass
- Ball valve – liquid line (shipped loose)
- Insulated suction lines
- Leg Kits
- Discharge air hood
- Sub cooling circuit on 5 – 22 HP models
- Variable speed EC motors only as head pressure control (see Bulletin B40-HPC-AG for details)
- QuickVac Evacuation and Refrigerant Recovery Valves
- Liquid line solenoid valve-(with standard 230 volt coil)-shipped loose
- Compressor Circuit breaker
- Current sensing relay – for use with Oil safety control (where applicable)
- Defrost heater contactor c/w fuse block
- Evaporator Fan contactor c/w fuse block
- Disconnect switch
- Disconnect Fusing
- Pump down toggle switch
- Lock out control circuit
- Hoffmann Speed control for condenser fan (replaces flooded valve)
- Time delay relay for compressor
- Mechanical Time Clock
- Defrost Kit
- Electronic Voltage/Phase Monitor
- SmartSpeed Fan Motor Technology Fan Motor Technology (See our Product Data and Specifications for full details (PDF))
- Limitrol+ Floating Head Pressure Control System (see Bulletin B40-LIMITROL-AG for details))
Application:
- High, Medium and Low Temperature Refrigeration applications.
- Indoor or Outdoor
Capacity:
- 1 to 22 HP for High, Medium, and Low Temperature Refrigeration applications.
Electrical:
- 208-230/1/60
- 208-230/3/60
- 460/3/60
- 575/3/60
- 220/1/50
- 200-220/3/50
- 380-400/3/50
Product Manuals & Specifications:
Product Data and Specifications – Generation D Models (for AWEF-Compliant Applications)
Product Data and Specifications – Generation C Models (for AWEF-Exempt Applications)
Installation Manual
Limitrol+ Application Guide
Head Pressure Control Application Guide
Lead Lag Control Panel
Related Sales Material:
All-Product Brochure
Limitrol+ Floating Head Pressure Control System Sell Sheet
SmartSpeed Fan Motor Technology Sell Sheet
Shafted EC Motors Sell Sheet
Additional Links:
About Heated And Insulated Receivers
Shafted EC Motors
About Limitrol+
Download AutoCAD Drawings – Generation “D” Units
Download AutoCAD Drawings – “C” Generation Units
Download High-Resolution Image
AWEF-FAQ
AWEF numbers for Bally Refrigeration AWEF-compliant condensing units
Cross-reference: Generation D (AWEF compliant) to C-Generation (AWEF non-compliant) equipment
Cross-reference: Generation D (AWEF compliant) scroll to C-Generation (AWEF non-compliant) hermetic or semi-hermetic equipment
Product Data and Specifications – Generation C Models (units produced pre-2020)
Service Parts:
Search for BES Parts In The Service Parts Database